I67992AT I67992AT kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16X1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5 -0,3 / =4
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
I68199 I68199 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16X1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
I69421 I69421 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16X1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 - 0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: No circuit
Circuit 4 - Open/close pressure [bar]:
No circuit
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
I74309 I74309 kelių grandinių apsauginis vožtuvas

techninė informacija:
Circuit 1 - Open/close pressure [bar]:
7,1 -0,4
Circuit 2 - Open/close pressure [bar]:
7,1 -0,4
KNORR-BREM
I80204 I80204 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
7,0 -0,3 / =4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
I93562 I93562 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 11,12,21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / 4,5+0,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
External series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
I93563 I93563 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 11,12,21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,9
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,9
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6,5-0,3 / >4,9
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,5-0,3 / >4,9
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
External series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
I99814 I99814 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with Bypass
Circuit 3 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with Bypass
Circuit 4 - Open/close pressure [bar]:
6,5-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal parallel supply to all Circuits
With Electrical pressure sensing: No
KNORR-BREM
II36008 II36008 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: Voss NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0 -0,3 / >7
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0 -0,3 / >7
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5 -0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5 -0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
KNORR-BREM
II36154 II36154 kelių grandinių apsauginis vožtuvas

techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,8-0,3 / >5,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,8-0,3 / >5,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6,3-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,3-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 2
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No