Filtruojant rezultatų nerasta!
II37679M4
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6.5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6.5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
8,0-0,2 / 6.5+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
8,0-0,2 / 6.5+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6.5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6.5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
8,0-0,2 / 6.5+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
8,0-0,2 / 6.5+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
II37680
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
techninė informacija:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
II37680004
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
techninė informacija:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 1 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 2 - Pressure Limiting [bar]: 10,0 +/-0,2
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
II3792213V
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: M22x1,5; 27,28: M12x1,5; IP,IPM
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: M22x1,5; 27,28: M12x1,5; IP,IPM
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >4,5
Circuit 3 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >4,5
Circuit 4 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
II37922N50
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: M22x1,5; 27,28: M12x1,5; IP,IPM
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: M22x1,5; 27,28: M12x1,5; IP,IPM
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
II37922R
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: M22x1,5; 27,28: M12x1,5; IP,IPM
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21,22,23,24,25,26: M22x1,5; 27,28: M12x1,5; IP,IPM
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,0 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
II38677F
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
II38677FM2
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,4+0,3 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: 10,4 +0,0/-0,4
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,4+0,1-0,2 / 6,1+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
II38745F
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
II38745F004
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
II38745FM2
kelių grandinių apsauginis vožtuvas
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
techninė informacija:
Air Inlet port(s) size: M16x1,5
Air Delivery port(s) size:
21,22,23,24: M16x1,5; 26: M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5+0,2 / 6,5+-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,2 / 5,9+-0,25
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: Yes
Paskiausiai peržiūrėta