K095475N49
oro ruošimo blokas
techninė informacija:
Air Inlet port(s) size: LA: M22x1,5
Air Delivery port(s) size:
LA: 23: M12x1.5, 24: M22x1,5, 25: :M16x1,5;
MCPV:
21,22,23,24: M16x1,5
Purge control: Electrical
Tyre Inflator port size: Not included
Unloader cut-out pressure [bar]:
9,5+0,4 programmable Customer
Unloader pressure control range [bar]:
programmable Customer
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,6-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: Yes
Exhaust Connector: Exhaust Silencer fitted
Heater Connector Type: Bayonet ISO 15170 A1 - 2.1.14
Heater Voltage [volts]: 24
Air dryer part number: K096756
Four circuit protection valve part number: K096082
Cartridge type: OSC
Semi Electonic Control: Yes
techninė informacija:
Air Inlet port(s) size: LA: M22x1,5
Air Delivery port(s) size:
LA: 23: M12x1.5, 24: M22x1,5, 25: :M16x1,5;
MCPV:
21,22,23,24: M16x1,5
Purge control: Electrical
Tyre Inflator port size: Not included
Unloader cut-out pressure [bar]:
9,5+0,4 programmable Customer
Unloader pressure control range [bar]:
programmable Customer
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,6-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,7+0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: Yes
Exhaust Connector: Exhaust Silencer fitted
Heater Connector Type: Bayonet ISO 15170 A1 - 2.1.14
Heater Voltage [volts]: 24
Air dryer part number: K096756
Four circuit protection valve part number: K096082
Cartridge type: OSC
Semi Electonic Control: Yes