Filtruojant rezultatų nerasta!
K100169 KNORR-BREM
oro ruošimo blokas
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21, 22, 23, 24:M16x1,5;;4/26: M12x1.5
Purge control: Timed Purge
Tyre Inflator port size: Not included
Unloader cut-out pressure [bar]: 9,3±0,2
Unloader pressure control range [bar]: 1,0 +0,4
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,9-0,3 / >= 5,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,9-0,3 / >= 5.5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >= 5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,9-0,3 / >= 5.5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: Yes
Exhaust Connector: Exhaust Silencer fitted
Heater Connector Type: Bayonet ISO 15170 A1 - 2.1.14
Heater Voltage [volts]: 24
Air dryer part number: no separately air dryer
Four circuit protection valve part number:
no separately FCPV
Cartridge type: OSC
Semi Electonic Control: No
techninė informacija:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size:
21, 22, 23, 24:M16x1,5;;4/26: M12x1.5
Purge control: Timed Purge
Tyre Inflator port size: Not included
Unloader cut-out pressure [bar]: 9,3±0,2
Unloader pressure control range [bar]: 1,0 +0,4
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,9-0,3 / >= 5,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,9-0,3 / >= 5.5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >= 5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,9-0,3 / >= 5.5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: Yes
Exhaust Connector: Exhaust Silencer fitted
Heater Connector Type: Bayonet ISO 15170 A1 - 2.1.14
Heater Voltage [volts]: 24
Air dryer part number: no separately air dryer
Four circuit protection valve part number:
no separately FCPV
Cartridge type: OSC
Semi Electonic Control: No